Laser Q-Switch HF Generators
From compact, low-power generators with housing surface cooling to 19 ‘‘ plug-in units with active fan cooling or closed water cooling, we develop and manufacture a large number of application-specific designed HF drivers for laser applications.
The devices work on ISM frequencies (27.12 / 40.68 MHz) or other frequencies as required. The switching characteristics and logic can be individually adapted to the necessary requirements of the intended laser system or its Q-switches.
Type
HF power [W]
Frequency [MHz]
Supply volt. [V]
On / off time [ns]
HLTM-80/24-16
Output power: 16 W
Frequency: 80 MHz
Switch-Off-Time: 10 ns
Overload protection: no-load / short-circuit proof at the output
Supply: 24 V DC
Housing: aluminum, colorless chromated, contact cooling
HLTMR-80/24-12
Output power: 12 W
Frequency: 80 MHz
Switch-Off-Time: 10 ns
Overload protection: no-load / short-circuit proof at the output
Supply: 24 V DC
Housing: aluminum, colorless chromated, contact cooling
HLT-27/24/50
Output power: 50 W
Frequency: 27.12 MHz
Switch-Off-Time: 20 ns
Overload protection: error message over-temperature, error-message SWR Overload
Supply: 24 V DC
Housing: aluminum, colorless chromated, contact cooling
HLT-40/13
Output power: 20 W
Frequency: 40.68 MHz
Switch-Off-Time: 10 ns
Overload protection: no-load / short-circuit proof at the output
Supply: 13 V DC
Housing: aluminum, colorless chromated, contact cooling
HLTR-80/24-12
Output power: 12 W
Frequency: 80 MHz
Switch-Off-Time: 10 ns
Overload protection: no-load / short-circuit proof at the output
Supply: 24 V DC
Housing: aluminum, colorless chromated, contact cooling
HLTX-200/24/3
Treiber für akusto-optische Modulatoren
Output power: 3 W
Frequency: 200 MHz
Switch-On/-Off-Time: ~166 ps
Overload protection: no-load / short-circuit proof at the output
Supply: 24 V DC
Housing: aluminum, colorless chromated, contact cooling
HLTX-250/24/6
Treiber für akusto-optische Modulatoren
Output power: 6 W
Frequency: 250 MHz
Switch-On/-Off-Time: ~166 ps
Overload protection: no-load / short-circuit proof at the output
Supply: 24 V DC
Housing: aluminum, colorless chromated, contact cooling
HLT-70
Output power: 2 x 35 W
Frequency: 27.12 / 40.68 MHz
Switch-Off-Time: 30 ns
Overload protection: no-load / short-circuit proof at the output
Supply: 110 … 270 V AC
Housing: switch cabinet assembly, sheet steel
HLT-31 DIGI
Output power: 30 W
Frequency: 27.12 / 40.68 MHz
Switch-Off-Time: 30 ns
Overload protection: no-load / short-circuit proof at the output
Supply: 110 … 270 V AC
Housing: switch cabinet assembly, sheet steel
HG-102
Output power: 100 W
Frequency: 27.12 / 40.68 MHz
Switch-Off-Time: 30 ns
Overload protection: no-load / short-circuit proof at the output
Supply: 110 … 270 V AC
Housing: sheet steel
HG-101
Output power: 100 W
Frequency: 27.12 / 40.68 MHz
Switch-Off-Time: 30 ns
Overload protection: no-load / short-circuit proof at the output
Supply: 110 … 270 V AC
Housing: aluminum, colorless chromated
HG-100
Output power: 100 W
Frequency: 27.12 / 40.68 MHz
Switch-Off-Time: 30 ns
Overload protection: no-load / short-circuit proof at the output
Supply: 110 … 230 V AC
Housing: aluminum, colorless chromated
HG-401
Output power: 400 W (4 x 100 W inter connectable)
Frequency: 27.12 / 40.68 MHz
Switch-Off-Time: 30 ns
Overload protection: no-load / short-circuit proof at the output
Supply: 110 … 270 V AC
Housing: 19”, aluminum, colorless chromated